Firmware v3.2.0
Firmware versions 3.0 and later are only compatible on OS0, OS1, and OSDome hardware versions Rev7 and later. Refer to firmware 2.x or earlier if you have Rev7 OS2, Rev 06 OS0/OS1/OS2, or earlier generation sensors.
Firmware v3.2.0
Date: February 2026
Added
- Zone Monitor: Added support for the new Zone Monitor feature.
- Window Signal: Added 8-bit Window Signal value for dirty or blocked window interpretation.
- Multicast: Added multicast routing support by allowing TTL configuration
> 1. - Default Gateway: Added the ability to set a static IP to specify a default route.
- Input-only MIO: Added the ability to query input levels of MIO pins.
- Frame Start Control: Added configurable start of frame functionality.
- OpenAPI: Included OpenAPI v3.1.1 specification on the sensor.
- IMU Profile: Added new
ACCEL32_GYRO32_NMEAIMU UDP packet format.
Improved
- Reflectivity: Improved accuracy and uniformity of Calibrated Reflectivity.
- IMU: Synchronous IMU improvements and bug fixes for the HTTP endpoint.
- Bloom: Blooming reduction to result in fewer False Positives (FP) and False Negatives (FN) near retro-reflectors. The feature is user-configurable with two modes available: Balanced (Default) and Minimize False Positives.
- Thermal Management: General thermal improvements compared to Firmware v3.1.
- Web UI: Comprehensive update to the web interface including support for Static IP Gateway, User Editable Data, OpenAPI spec, and Zone Monitor.
- Web UI API: Updated Web UI to use PUT with exact URIs to update individual configuration keys.
- API Validation: Improved validation of static IPv4 addresses.
- mDNS: Improved protocol compliance for mDNS.
- Firmware Update (FWUP): Improved status reporting via
update_statusunderapi/v1/system/firmware.
Fixed
- Thermal/TEC: Fixed issue causing unnecessary thermal cycling of the TEC; implemented full recovery from thermal shutdown with proper reinitialization.
- System Stability: Fixed TX-board initialization parameters and implemented uplink auto-reinitialization to recover from communication failures.
- Alerts: Updated
PHASE_LOCK_LOSTalert to include error amount in message for better diagnostics; addedWLP_STARTUP_FAILUREalert ifCALIBRATE_SENSORSstate fails. - Lidar Data: Suppressed missed lidar data alerts during diagnostic dump generation.
- Synchronization: Fixed issue where NMEA lock toggled constantly even when MPIO was disconnected.
- MIO: Fixed bug in
ENCODER_ANGLE_OUTmode for Multipurpose IO.
Changed
- Packet Header: FuSa configurable packet header now available.
- API Formatting: The config endpoint and
set_config_paramno longer accept dotted parameters; forward slash/must be used as a delimiter for beta parameters.
Removed/Deprecated
- TCP Command Server: Removed. TCP command support has been dropped; users must use the HTTP API.
- Undocumented API: Deprecated undocumented API commands.
- Legacy Parameters: Deprecated
/api/v1/configlegacy parameters. - Lidar Profile: Deprecated LEGACY lidar profile; will be removed in Firmware v4.0.
- IMU Profile: Deprecated LEGACY IMU profile; will be removed in Firmware v4.0.